麻豆一区二区99久久久久|在线播放国产AV蜜桃影像传媒|97久久超碰国产亚洲人最新|日韩激情无码免费毛片

  1. <table id="z0icw"></table>

    <var id="z0icw"><rt id="z0icw"><video id="z0icw"></video></rt></var>
    1. <var id="z0icw"><rt id="z0icw"></rt></var>
    2. <var id="z0icw"><rt id="z0icw"></rt></var>
            1. <var id="z0icw"><rt id="z0icw"></rt></var>
              <table id="z0icw"><cite id="z0icw"></cite></table>
            2. <table id="z0icw"><meter id="z0icw"></meter></table>

              Disposable Isolation Gown


              Description:

              Isolation Gown designed to protect health care patients and personnel from the transfer of microorganisms, body fluids and particulate material. Single use and disposable gown made of polypropylene. Product has been tested for chest and sleeves penetration by Hydrostatic Pressure Test and the results pass the AAMI different level requirements.

              Characteristic

              Specification

              Material

              PP+PE,SMS: "S" is short for "Spunbonded Polypropylene", "M" for "Melt Blown

              Color

              Blue/Green/Yellow/Purple

              Features

              Lightweight breathable gowns feature ties in back of neck and at waist for a secure, comfortable fit. Elastic cuffs at wrists keep the sleeves firmly in place and gather softly under gloves.

              Application

              Food process, Hospital ,Household , Laboratory,Hotel ,Painting and coating industry and so on

               


              Table 1:Gowns Type


               

              Type A

              Type B

              Type C

              Material

              PP+PE

              PET

              PP+PE with tap

              Colour

              Yellow

              Blue

              Yellow

              Classification

              AAMI PB70 Level 1

              AAMI PB70 Level 1

              AAMI PB70 Level 2

               

              Table 1:Gowns Type


              Ref. NO.

              Description

              Size

              Bag/Carton

              Bag Dimension(cm)

              Carton Dimension(cm)

              G.W.(KG)

              N.W.(KG)

              R120001

              Isolation Gown, Yellow, Level 1

              L

              10/100

              32*55

              58*38*28

              7.35

              6.28

              R120002

              Isolation Gown, Yellow, Level 1

              XL

              10/100

              32*55

              58*38*28

              8.95

              7.88

              R120003E

              Isolation Gown, Blue Level 1

              L

              10/100

              32*55

              42*28*34

              11.82

              12.5

              R120004E

              Isolation Gown, Blue Level 1

              XL

              10/100

              32*55

              42*28*34

              14.4

              15.1

              R120006

              Isolation Gown, Yellow, Level 2

              XL

              10/100

              32*55

              58*38*30

              8.4

              9.4

               

              The Guide to select gowns and other apparel.

              Safety starts well before the moment a clinician enters the patient’s room. The setting usage key and materials description as a guide to select right options for gowns in every situation.

              Setting usage guidelines

              The icons represented below should be used as a guideline in making gown selections for various needs and areas of your facility. Additionally, utilize the AAMI chart for the appropriate level gown.

              Materials descriptions

              Spunbond Polypropylene

              Standard, cost-effective and comfortable
              For basic infection control, this non-woven fabric bonds fibers together to form a single layer that is appropriate only for very minimal fluid exposure.

               

               

              SMS Material

              Balanced mix of protection and comfort
              Strong and breathable, Spunbond/Meltblown/Spunbond (SMS) is a multi-layer fabric composed of inner layers of meltblown polypropylene between outer layers of spunbond polypropylene that is ideal for extended wear. Light/medium weight SMS is appropriate for low amounts of fluid and heavy weight SMS may be appropriate for moderate contact with fluids.

               

               

              Coated Polypropylene (“Poly-coated”)

              Soft, spunbond polypropylene is coated with a layer of polyethylene (plastic) film.

               

               

              Polyethylene (Plastic) Film

              A single layer of polyethylene (plastic) film provides protection at an affordable cost.

               

               

              AAMI Level guide

              The Association for the Advancement of Medical Instrumentation (AAMI) standards are designed to help medical-device companies meet global standards for the safe use of medical devices. AAMI introduced the voluntary standard ANSI/AAMI PB70:2012, Liquid Barrier Performance and Classification of Protective Apparel and Drapes Intended for Use in Health Care Facilities,

              We're your source for AAMI compliant gowns. Choose the level you need, based on the green/orange/blue/purple color coding in the following chart.
               

              AAMI PB70 Guidelines

              ANSI/AAMI PB70 Barrier performance

              Test Method

              Test definition

              Requirement

              Anticipated fluid exposure

              AAMI Level 1

              Water resistance:
              Impact penetration AATCC 42

              AATCC 42
              Measures the resistance of fabrics to the liquid
              penetration of water by impact

              Water impact < 4.5 g

              Minimal
              fluid levels

              AAMI Level 2

              Water resistance:
              Impact penetration AATCC 42
              Water resistance:
              Hydrostatic pressure
              AATCC 27

              AATCC 42
              Measures the resistance of fabrics to the liquid
              penetration of water by impact
              AATCC 127
              Measures the resistance of fabrics to the liquid
              penetration of water by impact under constant and increasing hydrostatic pressure

              Spray impact < 1.0 g
              Hydrostatic Pressure
              > 20 cm

              Low fluid levels

              AAMI Level 3

              Water resistance:
              Impact penetration AATCC 42
              Water resistance:
              Hydrostatic pressure
              AATCC 27

              AATCC 42
              Measures the resistance of fabrics to the liquid
              penetration of water by impact
              AATCC 127
              Measures the resistance of fabrics to the liquid
              penetration of water by impact under constant and increasing hydrostatic pressure

              Spray impact < 1.0 g
              Hydrostatic pressure
              > 50 cm

              Moderate
              fluid levels

              AAMI Level 4

              ASTM F1671, Standard Test Method for Resistance of Materials Used in Protective Clothing to Penetration by Blood-Borne Pathogens Using Phi-X174 Bacteriophage
              Penetration as a Test System

              ASTM F1671  Measures the resistance
              of materials used in protective clothing to penetration by blood borne pathogens using a surrogate microbe under conditions of continuous liquid contact.

              PASS

              High fluid and viral barrier levels

               

              Style guide

              Key features like wrist, neck and back style can vary from gown to gown. Use this style guide to understand the differences.

               

              Wrist style options

              Neck style options


              Back style option


              1. <table id="z0icw"></table>

                <var id="z0icw"><rt id="z0icw"><video id="z0icw"></video></rt></var>
                1. <var id="z0icw"><rt id="z0icw"></rt></var>
                2. <var id="z0icw"><rt id="z0icw"></rt></var>
                        1. <var id="z0icw"><rt id="z0icw"></rt></var>
                          <table id="z0icw"><cite id="z0icw"></cite></table>
                        2. <table id="z0icw"><meter id="z0icw"></meter></table>